English

Cleanroom

Cleanroom for LCD repairing

 

 

 


[picture 1. Cleanroom for LCD repair in Thailand]

 

cleanroom of class100

 

[picture 2. cleanroom of class 1,000, Algeria]

 

1. What is a Cleanroom?

 

A cleanroom or clean room is an environment, typically used in manufacturing or scientific research, with a low level of environmental pollutants such as dust, airborne microbes, aerosol particles, and chemical vapors. More accurately, a cleanroom has a controlled level of contamination that is specified by the number of particles per cubic meter at a specified particle size. To give perspective, the ambient air outside in a typical urban environment contains 35,000,000 particles per cubic meter in the size range 0.5 μm and larger in diameter, corresponding to an ISO 9 cleanroom, while an ISO 1 cleanroom allows no particles in that size range and only 12 particles per cubic meter of 0.3 μm and smaller. In the pharmaceutical industry, clean rooms play a crucial role in the manufacturing of pharmaceutical products which are required to be free from microbial and particulate contamination and protected from moisture. Such pharmaceutical products are manufactured and manipulated in cleanrooms, which are fitted with HEPA and, if required, ULPA filters as well as dehumidifier systems.

 

2, Different class of electronic cleanroom?

 

(1) US FED STD 209E cleanroom standards

 

Class maximum particles/ft3 ISO
equivalent
≥0.1 µm ≥0.2 µm ≥0.3 µm ≥0.5 µm ≥5 µm
1 35 7.5 3 1 0.007 ISO 3
10 350 75 30 10 0.07 ISO 4
100 3,500 750 300 100 0.7 ISO 5
1,000 35,000 7,500 3000 1,000 7 ISO 6
10,000 350,000 75,000 30,000 10,000 70 ISO 7
100,000 3.5×106 750,000 300,000 100,000 700 ISO 8

 

(2) ISO 14644-1 cleanroom standards

 

Class maximum particles/m3 FED STD 209E
equivalent
≥0.1 µm ≥0.2 µm ≥0.3 µm ≥0.5 µm ≥1 µm ≥5 µm
ISO 1 10 2.37 1.02 0.35 0.083 0.0029  
ISO 2 100 23.7 10.2 3.5 0.83 0.029  
ISO 3 1,000 237 102 35 8.3 0.29 Class 1
ISO 4 10,000 2,370 1,020 352 83 2.9 Class 10
ISO 5 100,000 23,700 10,200 3,520 832 29 Class 100
ISO 6 1.0×106 237,000 102,000 35,200 8,320 293 Class 1,000
ISO 7 1.0×107 2.37×106 1,020,000 352,000 83,200 2,930 Class 10,000
ISO 8 1.0×108 2.37×107 1.02×107 3,520,000 832,000 29,300 Class 100,000
ISO 9 1.0×109 2.37×108 1.02×108 35,200,000 8,320,000 293,000 Room air

 

 

(3) BS 5295 cleanroom standards

 

  maximum particles/m3
Class ≥0.5 µm ≥1 µm ≥5 µm ≥10 µm ≥25 µm
Class 1 3,000   0 0 0
Class 2 300,000   2,000 30  
Class 3   1,000,000 20,000 4,000 300
Class 4     200,000 40,000 4,000

 

2. Construction Cost of LCD repair cleanroom

 

(1) Clean area 15m X 7m

(2) Air Handling Unit Installation Area 5m X 7m 

(3) Reference Price :  US$ 120,000

 

3. Contact


[Picture 3. Cleanroom Construction in Cuatitlan, Mexico]

 

If you had any interest on building LCD repair Cleanroom, please contact to hddtrade@gmail.com +82-10-2734-3535